COMMSTAT 4™ HVAC CONTROLLER

Our most comprehensive HVAC controller for air conditioners or heat pumps in a telecom shelter or enclosure.

A single CommStat 4 will control two redundant air conditioners or heat pumps, but has the capability to be daisy chained with a second CommStat 4 unit for controlling up to four air conditioners or heat pumps in a shelter. The CommStat 4 has seven outputs for remote alarms or notification.

A unique Marvair feature, the Comfort button, allows a service tech to easily change the temperature to provide a comfortable working environment. After 90 minutes, the temperature set points automatically revert back to the programmed temperature set points. The CommStat 4 also stores the last 10 ten faults that were registered. 

LEAD/LAG OPERATION

User selectable changeover from 1/2 to 7 days in 1/2 increments. If the lead unit loses power, the lag unit automatically becomes the lead unit with all the set points of the lead unit. A lead swap button alternates the lead and lag unit, allowing service techs to easily check the operation of each unit.

ALARMS

Dry contacts can be used for remote alarm or notification. Relays can be wired Normally Open (NO) or Normally Closed (NC).

  • High (Line) Voltage

  • Low (Control) Voltage

  • Lockout

  • Low Building Temperature

  • Smoke alarm

  • First Stage High Building Temperature

  • Second Stage High Building Temperature

  • Aux 1 & Aux 2

FEATURES

  • THERMOSTAT RANGE

    Cooling: 65° - 95°F (18° - 35°C) in 1° increments.

    Heating: 50° - 80°F (10° - 27°C) in 1° increments.

  • DIFFERENTIAL

    Adjustable ON-OFF differential for both Stage 1 and Stage 2

    Adjustable changeover differential between heating and cooling.

  • MAXIMUM VOLTAGE

    24 VAC

  • INPUTS

    Input power

    Modem Connection

    Control voltage

    Line Voltage

    Temperature Sensors

    Smoke Detector

    Hydrogen Detector

    Generator Relay

    Economizer Mode Status Monitoring

    Lockout Relay

    Aux 1/ Aux 2

  • EASE OF INSTALLATION

    Wiring connection insensitive to phasing of the HVAC units.

    Easy terminal connections for thermostat wire.

    Remote temperature sensors insure accurate temperature readings.

  • OPERATING RANGE

    -40°F through 150°F

    (-40°C through 66°C)

  • MINIMUM VOLTAGE

    18 VAC

  • MAXIMUM VOLTAGE

    30 VAC

  • EASE OF INSTALLATION

    Wiring connection insensitive to phasing of the HVAC units.

    Easy terminal connections for thermostat wire.

    Remote temperature sensors insure accurate temperature readings.