ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 TON)

GENERAL DESCRIPTION

Industrial Climate Engineering’s air conditioners are used primarily to cool electronic and mechanical equipment shelters (E-Houses). Due to the high internal heat load, these shelters require cooling even when outside temperatures are 60°F (15°C) and below. ICE air conditioners have the necessary controls and components for operation during these temperatures. All models use the non-ozone depleting R-410A refrigerant.

ICE air conditioners are installed on the exterior of the building – no interior space is required. Two openings in the wall allow for the conditioned (supply) air to be discharged into the building and for the indoor air to return to the air conditioner.

A sealed condenser fan motor permits operation in hot, dusty environments. The saw tooth fan blade delivers both excellent efficiency and extremely quiet operation.

The direct drive backward inclined motorized impellor evaporator motor provides high aerodynamic efficiency in a compact design. The optimized blade geometry provides excellent air flow at a minimum sound level. Direct drive eliminates all belts and pulleys. A scroll compressor with R-410A refrigerant ensures years of dependable service even in the harshest of operating conditions. When outside air is required to provide pressurization, optional fresh air dampers can be field installed in openings in both the left and right side panels. When no outside air is desired, these openings are covered with blank-off panels.

SAFETY LISTED

ICE air conditioners are built to UL standard 1995, 4th edition and CAN/CSA C22.2, No. 236-11. The units are tested in accordance to the ASHRAE standard. The air conditioners are commercial and industrial units and are not intended for use in residential applications.

FEATURES

  • HIGH EFFICIENCY

    Thermal Expansion Valve Improves Efficiency

    High Efficiency Scroll Compressor

    Lanced Fins On the Evaporator and Condenser

    Coils Improve Heat Transfer

  • BUILT-IN RELIABILITY

    High and Low Pressure Switch with Lockout

    Adjustable Short Cycle Protection

    Phase Monitor

    High Compressor Temperature Switch

    Internal Motor Overload Protection

  • RUGGED CONSTRUCTION

    Copper Tube, Aluminum Fin Evaporator &

    Condenser Coil

    Field Or Factory Installed Heaters On Discharge

    Side of Evaporator Coil

    Baked On Finish Over Galvanneal Steel

Data Sheet and Manual