INTERFACE AND FUNCTION
User-friendly English-language menus (no obscure numeric codes) on a 64 x 128 pixel, dot-matrix LCD display with 5 buttons for data selection and entry
Built-in, factory-tested libraries of configurable application control sequences
Integral energy management control with deadband heating and cooling setpoints and other advanced features
Schedules can easily be set uniquely by entire week (Mon.–Sun.), weekdays (Mon.–Fri.), weekend (Sat.–Sun.), individual days, and/or holidays—or “learned” automatically via motion sensing
Six On/Off and independent heating and cooling setpoint periods are available per day
Three levels of password-protected access (user/operator/administrator) prevent disruption of operation and configuration
Integral temperature, humidity, motion, and CO2 sensor options
A 72-hour power (capacitor) backup and a real-time clock for network time synchronization or full stand-alone operation
BACNET STANDARDS
Meets or exceeds BACnet AAC specifications in the ANSI/ASHRAE BACnet Standard 135-2008
INPUTS AND OUTPUTS
Three or six analog inputs for use with external devices such as mixed air temperature, fan status, outside air, and remote CO2
Analog inputs accept industry-standard 10K ohm thermistor sensors or dry contacts
Inputs can be configured via a switch for 10K ohm pull-up resistors (for unpowered contacts or devices) or 0–12 VDC
Input overvoltage protection (24 VAC, continuous)
12-bit analog-to-digital conversion on inputs
Seven NO, SPST (Form “A”) relays carry 1 A max. per relay or 1.5 A per bank of 3 relays (relays 1–3 and 4–6) @ 24 VAC/VDC
CONNECTIONS
Screw terminal blocks, wire size 14–22 AWG, for inputs, outputs, power, and BACnet network
Integral peer-to-peer BACnet MS/TP LAN network communications on all devices (with configurable baud rate from 9600 to 76.8K baud)
A four-pin EIA-485 data port on the underside of the case enables easy temporary computer connection to the BACnet network
“E” versions add an RJ-45 jack
For detailed specifications, performance, and efficiency information, download the Product Data Sheet from the document list on this page.
THERMOSTAT/CONTROLLER
The MAR7000 is a controller and sensors in a single, attractive package that creates a flexible solution to stand-alone control challenges or BACnet network challenges.
FEATURES
-
AIR CONDITIONER ALARMS
Heat pump unit, with up to two compressor stages, and with optional auxiliary heat, emergency heat, dehumidification, and/or fan status .
A/C, with up to two H/C stages, and with optional economizer, dehumidification, and/or fan status.